In response to the testing and R&D needs of electronic components such as semiconductors and automotive electronics, ESPEC(Guangdong)has developed a smaller capacity -Compact Rapid Temperature Change(humidity) Chamber -GMS/G series.
Among them, the standard rated voltage of GMS/G-100-15 products is single-phase 220VAC, and three-phase 380VAC modification can be selected, which can meet the equipment usage needs of customers in civil office areas such as research institutions and universities, as well as the more common electricity needs of other industrial sites. The GMS/G-100-20 chamber comes standard with three-phase 380VAC voltage, which has a wide range of applications. At the same time, the advantage of low power and fast rate change of temperature makes more demanding semiconductor testing requirements possible.
Strong Temperature performance
A fast temperature rise and fall rate: 15℃/min、20℃/min;Pull Down rate:15℃/min、20℃/min is available.
Humidity range: 10% ~ 98%rh.
(*Temperature range: -45℃?+155℃)
GMSG/100-15 models: Single-phase 220VAC,can meet more electricity requirements
Single-phase 220VAC, which is suitable for industrial and residential power supply specifications, can meet the equipment power requirements of customers in research institutions, universities and other residential office areas.
Three phase 380VAC voltage options are available for selection, with a wider range of applications.
GSM/G-100-20 chamber: Three phase 380VAC, meeting the electricity requirements of more industrial sites
Low power and fast rate change of temperature can meet more demanding semiconductor testing requirements.
Small and exquisite body, compact structure, easy to move
Miniaturization of the chamber structure design, can effectively save configuration space;
Inner tank volume of 100L, size width 600mm, depth less than 1400mm, volume less than 1.1m3, suitable for most residential and commercial elevators in China (GB/T7025.1);
Standard universal wheels enable the chamber to move freely.
Air-cooled specifications as standard for ease of movement and installation
It also eliminates the cost and space for customers to configure cooling water towers.
More ergonomic operation touch screen design
Through the multi-angle adjustment of the touch screen, it can meet the operation needs of users of different heights and the best view, more convenient and comfortable.
Maintain the advantages of GF series
Balanced Temperature (&Humidity)Control system(BTHC system)and PID control function.
Interface (option)for device communication can be selected between RS-485, GPIB,Web Lan and RS-232C.
Cable ports on both sides (θ50mm) as standard to allow easy wiring access.
| Description | Model | Temp. Range | Hum. Control | Hum. range rh | Volume | Inside dimensions in mm (WxHxD) | Outside dimensions in mm (excl. projection)※3 | Heat up & pull down※4 |
| Compact Rapid Temperature Change(humidity) Chamber | GMS-100-15 | -70℃~+180℃ | YES | 10%~98%rh | 100L | 400 x 500 x 500 | 600 x 1380 x 1382 | 15 K/min. |
| Compact Rapid Temperature Change(humidity) Chamber | GMS-100-20 | -70℃~+180℃ | YES | 10%~98%rh | 100L | 400 x 500 x 500 | 600 x 1460 x 1382 | 20 K/min. |
| Compact Rapid Temperature ChangeChamber | GMG-100-15 | -70℃~+180℃ | NO | —— | 100L | 400 x 500 x 500 | 600 x 1380 x 1382 | 15 K/min. |
| Compact Rapid Temperature ChangeChamber | GMG-100-20 | -70℃~+180℃ | NO | —— | 100L | 400 x 500 x 500 | 600 x 1460 x 1382 | 20 K/min. |
※1 The temperature chamber's performance values are based on GB/T5170.2,and IEC60068-3-5.And humidity chamber's performance values are based on GB/T5170.5 and IEC60068-3-6.Performance figures aregiven for a +23℃ ambient temperature, relative humidity 65±20% RH, rated voltage, with no specimens inside the test area.
※2 The temperature inside chamber is +20℃.
※3 Excluding protrusions.Dimensions in [] included protrusions.
※4 This temperature Heat up & pull down rate is the value of the rate that 10% before and after the total temperature interval is removed.