Our temperature Chambers are suitable for a broad range of applications from high-temperature testing, to heat treatment or drying for production lines,which widely used in aviation, automotive, electronic parts, materials, energy, chemical, medical, pharmaceutical and other industries.
Contact1.High performance chamber
A temperature-indication controller with an advanced PID operation, and a special chamber configuration provide unmatched oven performance. Temperature uniformity, temperature constancy, temperature heat-up rate, and temperature recovery time are performed with the upmost reliability.
2.Several volumes are available in horizontal models.
3.Standard program instrumentation can suit various applications:
·Features programmed operation with operational settings such as constant mode and automatic start/stop. Suitable for heat treatment, drying, and similar production-line applications.
·Suitable for a range of applications from temperature-characteristics testing to heat treatment and drying. Programmed operation now allows storing 10 patterns, each up to 20 steps. Provides a wide range of functions, including temperature ramp settings and a maximum of 999 repeat cycles.
4.Easy setup with on-screen display.
5.Interface (option)for device communication can be selected between RS-485 and RS-232C.
6.Energy Saver Duct (PH series)
Energy saving approximately 20% by heat recycling from exhaust through the duct to maintain temperature while damper opens (PH series).
7.Safety measure
Triple safety mechanisms are employed for excessive overheating.
8.Core parts are inported from Japan and America,which are same with the ESPEC CORP.
Description | Model | Temp. Range | Hum. Control | Hum. range rh | Volume | Inside dimensions in mm (WxHxD) | Outside dimensions in mm (excl. projection) |
Temperature Chamber(horizontal) | GPH-10 | (RT+20℃)~+200℃ | NO | — | 91L | 450×450×450 | 1040×820×635 |
Temperature Chamber(horizontal) | GPH-20 | (RT+20℃)~+200℃ | NO | — | 216L | 600×600×600 | 1190×970×785 |
Temperature Chamber(horizontal) | GPH-30 | (RT+20℃)~+200℃ | NO | — | 512L | 800×800×800 | 1500×1210×1065 |
Temperature Chamber(horizontal) | GPH-40 | (RT+20℃)~+200℃ | NO | — | 1000L | 1000×1000×1000 | 1730×1480×1275 |
Temperature Chamber(horizontal) | GPH-H10 | (RT+20℃)~+300℃ | NO | — | 91L | 450×450×450 | 1040×820×635 |
Temperature Chamber(horizontal) | GPH-H20 | (RT+20℃)~+300℃ | NO | — | 216L | 600×600×600 | 1190×970×785 |
Temperature Chamber(horizontal) | GPH-H30 | (RT+20℃)~+300℃ | NO | — | 512L | 800×800×800 | 1500×1210×1065 |
Temperature Chamber(horizontal) | GPH-H40 | (RT+20℃)~+300℃ | NO | — | 1000L | 1000×1000×1000 | 1730×1480×1275 |
※The temperature chamber's performance values are based on GB/T5170.2,and IEC60068-3-5.And humidity chamber's performance values are based on GB/T5170.5 and IEC60068-3-6.Performance figures aregiven for a +23℃ ambient temperature, relative humidity 65±20% RH, rated voltage, with no specimens inside the test area.
Flange connects an exhaust duct to the chamber to exhaust hot from the chamber.
External diameter 87 mm.
Installed for mobility.
Specifications:Adjustable type 4pcs/set.(Including leveling feet 4pcs).
Outputs chamber temperature .
Preparation of a power cable,temperature sensor and a grounding wire for additional installation in the future.
Records temperature and humidity of each section such as the temperature inside the chamber.
Communication ports to connect the chamber to a PC.
Alternatives:Web(Lan)/RS-485/RS-232C. GPIB(not standard option).
Used for the placement of specimens in the test area.
Same as standard shelf.
*Shelf for H-(H)30/40/V-(H)33 type is punched plate.
A through hole provide on the wall of chamber。
Available dimensions: θ50/θ100
*1.without rubber plug and with cap.
*2.Could be added into the wall of chamber(standard position only ).Non-standard posotion please Inquire the sale company for details.
*3.Ifseveral cable ports are installed,the sueface temperature may rise or the chamber may not be able to meet standard performance.
Comes with the cable port. Prevents airleakage from the cable port.
Inside diameter: θ50/θ100
*1.The rubber plug cannot be used when operating the chamber at+200℃ or higher.
Automatically opens or closes synchronously with program operation for ventilation and fast cooling of chamber temperature.
Allows low air velocity in the chamber.Use when test require low airflow velocity or constant velocity.
Setting value rang:4 levels.
Safety device.
Purpose: This contact signal terminal is for sending error alerts to a remote location during safety actions.
*1 Unable to be fitted together with three Color Status indicator Warning Lights .
Safety device,enables manual emergency stop of the chamber.
*Purpose:Protecting the specimens and chambers.
Safety device.
Purpose: Provides a view of the chamber status from a remote location.
With buzzer/Without buzzer
*1:Unable to be fitted together with Alarm output terminal.
*2:Please contact the sales company if you need to change the action and light sequence.
When stacking two chambers,this plate couples the top and bottom chambers securely.
*Only available for GPH-(H)20 type.
Lift the device up,make it easier and more convenient to put in and take out specimens from the lower area inside chamber.
ParameterLift the device up,make it easier and more convenient to put in and take out specimens from the lower area inside chamber.
ParameterLift the device up,make it easier and more convenient to put in and take out specimens from the lower area inside chamber. More beautiful exterior with the door.
Available for the H-2,H-3 type stand of GPH-(H)20/30.
Installed on stand for mobility.
Available for stand L-2,M-2,H-2(Horizontal),and stand MV-23,MV-26(Vertical).
Test according to GB standard and issue test report.
*Base on the actual machine test results and for customer reference only. The report does not have the qualificationas a third-party testing agency.
Test report issue by ESPEC guangdong,
Same as standard accessories. shipped with chamber.